One of the challenges faced by modern medicine is finding new methods of functional imaging of biological tissues in patients that allow detection of early tumor response to treatment. One of such methods proposed in this work is multimodal optical coherence tomography (MM OCT). It combines cross-polarization OCT (CP OCT) for visualization of tissue structure and assessment of connective tissue health, OCT-based microangiography (OCT MA) for visualization of the vasculature, and OCT- based elastography for measuring tissue stiffness. The efficacy of this method was tested during the course of photodynamic therapy (PDT), as major PDT targets are cellular and vascular components of a tumor. The experiments were carried out on the CT26 colon carcinoma transplanted into the mouse ear. It was shown that the efficacy of PDT can be assessed using MM OCT. For example, CP OCT can help differentiate between necrotic and intact tumors; OCT MA detects blood circulation defects that lead to slower blood circulation or circulatory stagnation followed by tumor death. OCT-based elastography is helpful in assessing stiffness of normal and pathological tissues.
VIEWS 5011
Knowing the histology of cervical cancer (squamos cell carcinoma or adenocarcinoma) is important in deciding on the best treatment plan. We have studied the role of dynamic contrast-enhanced magnetic resonance imaging in the differential diagnosis of cervical cancer. We examined 90 patients between 23 and 78 years of age (mean age was 43.5 years) with histologically distinctive stage IIb–IVb cervical cancers. Scanning was performed on Magnetom Espree 1.5T and Magnetom Skyra 3.0T scanners (Siemens, Germany) using gadobutrol (Gadavist by Bayer, Germany). On T1-weighted images, signal intensity and its rate of change were significantly higher for adenocarcinomas compared to squamos cell carcinomas (p <0.04) from the 20th second after gadobutrol had been delivered to the tumor. With squamos cell carcinomas, the time-intensity curve (showing the dependence of signal intensity on the time elapsed after gadobutrol had been delivered to the tumor) had two phases: a short phase of a relatively slow accumulation of the contrast agent with the subsequent plateau or even signal intensity reduction. The pattern of gadobutrol accumulation allows differentiating between histological types of tumors. Based on the resulting curves, a pharmacokinetic model can be described for each tumor type. Postcontrast images are useful in determining tumor differentiation grade. Specifically, the signal from a well-differentiated adenocarcinoma is the most inhomogeneous one (p <0.03). The method described in this work does not imply that histological analysis is unnecessary and can be recommended as a supplementary diagnostic tool.
VIEWS 4921
In ophthalmology, excimer lasers are used for treating different refractive disorders. The performance of an excimer laser station can be assessed by a number of criteria, such as cornea surface smoothness after the ablation, differences between the diameter of the postoperative optical zone that received full correction and the diameter of the programmed optical zone, and cornea heating during the surgery. The article presents the results of the assessment of three Russian excimer laser systems: MicroScan-PIC 100 Hz, MicroScan-Visum 300 Hz and MicroScan-Visum 500 Hz (Optosystems, Russia). The smoothness of the ablated surface was measured by New View – 5000 Zygo interferometer (Zygo Corporation, USA). Using PMMA plates, the ablated surface was formed tenfold with each laser as an imitation of the 3.0 D myopia surgical correction, with the optical zone diameter of 6 mm and the transition zone diameters of 2.3 mm for MicroScan-PIC 100 Hz and of 1.9 mm for MicroScan- Visum 300 Hz and MicroScan-Visum 500 Hz. Thermal processes in the cornea were studied in 15 grey chinchillas over 1 year old with a weight of 2–3 kg. With each of the laser systems, phototherapeutic keratectomy was performed on 5 eyes. The smoothest ablated surfaces were formed by MicroScan-Visum 500 Hz. Cornea temperature was the highest here (+3.95 °С by the end of treatment), but still within the range of values acceptable for modern scanning type lasers.
VIEWS 4906