Copyright: © 2026 by the authors. Licensee: Pirogov University.
This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (CC BY).

OPINION

Wearable skin sensors for continuous lactate monitoring in eccrine sweat during physical exercise

Demin NA1 , Shishkin AA1 , Perevoshchikov DV1 , Lyakhmun DN1 , Shafigullin RR1 , Ostanin OE1 , Polyaev BA1 , Pleshchev IE2
About authors

1 Pirogov Russian National Research Medical University, Moscow, Russia

2 Yaroslavl State Medical University, Yaroslavl, Russia

Correspondence should be addressed: Oleg E. Ostanin
Ostrovityanova 1, Moscow, 117513, Russia; ur.xednay@1102gelo.ninatso

About paper

Author contribution: Demin NA — concept, literature review, manuscript writing; Shishkin AA — literature review, editing; Perevoshchikov DV, Shafigullin RR — evaluation of technical aspects of wearable sensor systems, editing; Lyakhmun DN — evaluation of lactate determination aspects, editing; Ostanin OE — literature review, manuscript writing and preparation for publishing; Polyaev BA — editing, expert control; Pleshchev IE — assessment of issues related to physical culture and sports, editing.

Received: 2026-09-22 Accepted: 2026-10-14 Published online: 2026-10-22
|

Determination of capillary blood lactate levels remains a standard invasive method to assess the metabolic response to physical exertion, but requires repeated sample collection and laboratory analysis. This increases the procedural burden on the athlete and makes the continuous monitoring during the training or functional testing almost impossible. Eccrine sweat represents an accessible noninvasive medium suitable for integration with wearable sensor systems. The technical feasibility of continuous lactate monitoring in sweat has been already demonstrated in a number of studies. The study aimed to assess the potential of using wearable skin sensor systems for continuous lactate level determination in eccrine sweat during physical exercise. Operating principles of sensor systems, physiological characteristics of lactate dynamics in sweat, and requirements for the measurement reliability and reproducibility were considered. In our opinion, the eccrine sweat lactate monitoring should be considered as not only an alternative for the conventional capillary blood lactate monitoring, but also an independent approach to non-invasive monitoring when performing the functional testing of athletes. However, it is necessary to determine the method diagnostic accuracy and reproducibility for its full implementation.

Keywords: lactate, sports medicine, non-invasive lactate monitoring, wearable sensor systems, functional diagnostics

КОММЕНТАРИИ (0)